Industrial, Commercial, and Construction portable Air conditioner for rent Quickly, Quietly, Effectively and Efficiently
Within Dubai, Abu Dhabi, Sharjah & Ajman
- we provide Portable air conditioners for computer server rooms, data centers and telecommunication rooms independent of building’s HVAC system.
- temporary cooling support for existing HVAC systems during maintenance operations.
- Spot cooling for factories, and production lines.
- backup air conditioning during emergencies
- dehumidifiers to bring protect sensitive products.
QUICK RESPONSE : we offer rental service just in time, 24-hr delivery within Dubai direct from the Local warehouse stock.
HIGH QUIETLY : Our portable industrial air conditioners runs smoothly without adding any humidity with low-noise operation for acceptable sound levels. best quality evaporator and condenser fans and evaporators for best operation long-run without any maintenance, mobile A/C units.
PERFORMANCE: Our outdoor industrial spot A/C delivers best performance and can handle high ambient temperatures and altitudes. This device self-protect in harsh areas and built to last long all-year regardless of conditions.
EASY TO USE: Just plug AND PLAY. all our portable AC’s are single phase and they don’t need any special wiring or electrical. they cost costs less to operate.
Cooling Capacity, BTU/hr1 | 14,000 | 17,600 | 29,600 | 42,200 | 77,500 | 76,500 |
power supply 2 voltage/phase/amps | 115/60/1/15 | 115/60/1/15 | 230/60/1/20 | 230/60/1/30 | 230/60/1/60 | 460/60/3/20 |
Thermostat control3 | Mechanical | Mechanical | Mechanical | Mechanical | Mechanical | Mechanical |
Metering device | TX Valve | TX Valve | TX Valve | TX Valve | TX Valve | TX Valve |
Total power consumption, kW | 1.3 | 1.4 | 2.9 | 4.2 | 8.7 | 9.3 |
Current consumption, amps | 11.7 | 12 | 12.5 | 18.3 | 37.8 | 13.2 |
Recommended circuit amps | 15 | 15 | 20 | 30 | 60 | 20 |
NEMA plug type | 5-15P | 5-15P | 6-20P | 6-30P | wired | wired |
CER rating | 10.4 | 12.8 | 10.3 | 10 | 8.9 | 8.3 |
Evaporator CFM, free discharge | 350 | 600 | 750 | 1,200 | 2,300 | 2,300 |
Condenser CFM | 500 | 1,000 | 1,000 | 1,500 | 3,900 | 3,900 |
Maximum esp, in wc | 0.1 | 0.1 | 0.1 | 0.1 | 0.5 | 0.5 |
Maximum duct length, ft | 40 | 40 | 40 | 40 | 40 | 40 |
Condensate-pump head, ft | 15 | 15 | 15 | 15 | 15 | 15 |
Operating limits, (min-max) °F | 65-105 | 65-110 | 65-105 | 65-105 | 65-110 | 65-110 |
Sound level, dB | 57 | 63 | 63 | 67 | 71 | 71 |
R-22 charge, oz4 | 32 | 52 | 54 | 80 | 110 | 110 |
l x w x h, in | 26 x 20 x 34 | 29 x 28 x 41 | 29 x 28 x 41 | 30 x 28 x 51 | 42 x 30 x 70 | 42 x 30 x 70 |
Weight, net wt/shipping wt, lb | 163/205 | 232/286 | 251/305 | 336/395 | 650/685 | 650/685 |